SKU : NS-HIKVI DS-3T1306P-SI/HS
DS-3T1306P-SI/HS
4 Port Fast Ethernet Smart Harsh POE Switch
Visualized topology management
Network health monitor
Layer 2 features: PoE watchdog, STP/RSTP, VLAN, SNMP, QoS, ERPS, etc
-30 °C to 65 °C wide temperature range in harsh environment
The Hikvision DS-3T1306P-SI/HS is a professional-grade smart managed PoE switch from Hikvision's Pro-Series network infrastructure lineup — delivering intelligent Power over Ethernet switching capability specifically engineered for IP surveillance camera deployments requiring the combination of smart management features, professional PoE power delivery, and Hikvision ecosystem integration that small-to-medium professional security installations demand. As a smart managed switch, the DS-3T1306P-SI/HS occupies the valuable middle ground between simple unmanaged PoE switches — which provide no network visibility or control — and full enterprise managed switches — which provide extensive but often unnecessary complexity for focused surveillance network deployments. The Pro-Series smart management features provide the network visibility, PoE power monitoring, and device management capability that professional security installers and IT administrators need to effectively deploy, monitor, and maintain IP camera networks without the configuration complexity of full managed switch platforms. The integrated PoE capability eliminates separate power supply requirements for connected IP cameras — delivering both network connectivity and electrical power to Hikvision IP cameras and other PoE-compatible devices through a single Ethernet cable, dramatically simplifying installation and reducing the electrical infrastructure requirements of professional surveillance deployments. For security integrators, professional installers, and IT professionals deploying Hikvision IP camera systems who want smart management capability alongside reliable PoE power delivery in a compact professional switch, the DS-3T1306P-SI/HS is the complete Pro-Series PoE switching solution.
Compatibility / Use Cases
Small professional IP camera installations — 2-4 camera deployments requiring smart managed PoE switching
Hikvision IP camera system deployments — DS-2CD series, ColorVu, AcuSense camera network connectivity
Remote camera cluster distribution — field-deployed PoE switch at camera cluster locations
Smart home and small office surveillance requiring professional-grade managed PoE capability
Retail and small commercial surveillance — shopfront, office, and small business camera networks
PoE camera network expansion adding managed PoE switching to existing surveillance infrastructure
Professional installer deployments requiring PoE Watchdog automatic camera recovery capability
Why This Product Stands Out
The Hikvision DS-3T1306P-SI/HS stands out in the small PoE switch market through its Pro-Series smart management platform — delivering network visibility, PoE power monitoring, PoE Watchdog automatic camera recovery, QoS prioritization, and VLAN segmentation in a compact professional switch specifically optimized for Hikvision IP camera ecosystem integration. The PoE Watchdog automatic camera reboot capability is particularly significant for professional surveillance deployments where camera reliability directly affects security coverage continuity — providing the automated fault recovery that eliminates manual on-site intervention for common camera freeze events. For security integrators and professional installers who want smart managed PoE capability with Hikvision ecosystem optimization in a compact, installation-flexible professional switch, the DS-3T1306P-SI/HS delivers the complete Pro-Series PoE switching solution.
| General | |
| Shell | Metal material |
| Net Weight | 0.4 kg (0.8 lb) |
| Gross Weight | 1.0 kg (2.2 lb) |
| Dimensions (W × H × D) | 158.00 mm × 101.20 mm × 31.60 mm (6.20'' × 3.90'' × 1.20'') |
| Operating Temperature | -30 °C to 65 °C (-22 °F to 149 °F) |
| Storage Temperature | -40 °C to 85 °C (-40 °F to 185 °F) |
| Operating Humidity | 5% to 95% (no condensation) |
| Relative Humidity | 5% to 95% (no condensation) |
| Power Supply | 48VDC, 1.36A |
| Installation Mode | Desk-Mounted,Rail |
| Max. Power Consumption | 65 W |
| Power Consumption in Idle | 5 W |
| Surge Protection | 6 kV |
| Network Parameters | |
| Ports | 4 × 10/100 Mbps PoE port,1 × Gigabit RJ45 port,1 × Gigabit fiber optical port |
| MAC Address Table | 2 K |
| Switching Capacity | Whole-Device Performance: 14 Gbps Port Performance: 4.8 Gbps |
| Packet Forwarding Rate | Whole-Device Performance: 10.42 Mpps Port Performance: 3.57 Mpps |
| Internal Cache | 1 Mbits |
| Software Function | |
| Long Range | Ports 1 to 4: up to 300 m. Long range performance may vary depend on camera model or cable condition. |
| Port Isolation | Ports 1 to 4: port isolation mode to improve network security Ports in an isolation group cannot communicate with each other, but they can communicate with ports outside the isolation group. |
| PoE Watchdog | Ports 1 to 4: auto detect and restart the cameras that do not respond. |
| QoS | QoS is used to allocate bandwidth to different services so as to provide end-to-end service quality assurance. Support port-based priority configuration. Support SP, WRR priority schedule mode. |
| VLAN | VLAN is used for network scale planning and network health improvement. Support 802.1Q. Configurable VLAN ID from 1-4094. Support Trunk, Access port mode. Support Max. 4094 VLAN. |
| HPP | Support one-click activation and remote management via Hik-Partner Pro. Functions supported: 1. Display the port rate. 2. Display the port bandwidth utilization rate. 3. Display the PoE power usage. 4. Display topology information. 5. Display the alarm status. 6. Restart ports and devices. 7. Enable port long-rage mode. 8. Remotely upgrade the device. |
| Loop Prevention | Loop prevention is used to prevent the switching network from forming loops, which will seriously affect network communication. Disabled by default. Support 802.1D STP. Support 802.1w RSTP. |
| System Maintenance | Support device management via web. Support DHCP Client. Enabled by default for dynamic assignment of management IP addresses. Support Super IP, which is a fixed IP address (10.180.190.200) for direct access. Support management via Hik-Central Pro. Support remote management via Hik-Partner Pro. Support cable detection. Abnormal open circuits and short circuits as well as network cable length can be detected. Support 802.1ab LLDP for peer device discovery. Support port mirroring for fault locating. |
| Port Rate-Limiting | Port rate-limiting is used for port bandwidth adjustment to prevent network congestion. |
| Storm Control | Storm control is used to prevent switch ports from being blocked by broadcast or multicast storms in the LAN, which may affect network communication. Support port rate limiting based on broadcast, multicast, and unknown unicast packets. |
| DHCP Snooping | DHCP Snooping can prevent unauthorized connections to DHCP servers from disrupting the network and affecting normal network communication, and only allow DHCP packets from trusted ports to pass through. Disabled by default. |
| ACL | Support ACL definitions based on source/destination MAC address, source/destination IP address, IP protocol type. Support ACL application on ports. Support IPv4 ACL and MAC ACL configurations. Support inbound ACLs. |
| PoE Power Supply | |
| PoE Standard | IEEE 802.3af,IEEE 802.3at |
| PoE Power Pin | 8-pin power: 1/2(-), 3/6(+), 4/5(+), 7/8(-) |
| PoE Port | PoE: Ports 1 to 4 |
| Max. Port Power | 30 W |
| PoE Power Budget | 60 W |
| Approval | |
| EMC | CE-EMC (EN 55032: 2015+A11: 2020, EN IEC 61000-3-2: 2019, EN 61000-3-3: 2013+A1: 2019, EN 50130-4: 2011+A1: 2014, EN 55035: 2017+A11: 2020) |
| Safety | CB (AMD1:2009, AMD2:2013, IEC 62368-1: 2014 (Second Edition), CE-LVD (EN 62368-1: 2014+A11: 2017) |